Medinol reports positive clinical results for Elunir elastomer-coated drug-eluting stent

1897

Twelve-month clinical results from Medinol’s BIONICS study have demonstrated that the company’s Elunir stent has a good safety profile, among other positive results.

The study was conducted to evaluate Elunir, Medinol’s elastomer-coated drug-eluting stent. The global pivotal study enrolled 1,919 patients from 76 sites in eight countries. The BIONICS results were highlighted in the opening Late Breaking Trial session of the 28th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium in Washington, DC, USA.

The study data will be submitted to the US Food and Drug Administration to support regulatory approval of Elunir for the treatment of patients with narrowing or blockage of their coronary arteries.

The BIONICS study, a global, prospective, randomised, multicentre, non-inferiority clinical trial was designed to include a “more comers” population, i.e. one that closely represents the real-world patient population. The Elunir Stent (study name Bionir) was compared to the Resolute Integrity Stent (1:1 randomisation). Key results from the study include:

  • For its primary endpoint, target lesion failure (TLF), Elunir demonstrated a rate of 5.4% at 12 months compared to an identical rate of 5.4% for Resolute (p=0.0013 for non-inferiority). TLF was defined as the composite of cardiac death, target vessel MI, and clinically driven TLR.
  • Good safety profile, with a low definite/probable stent thrombosis rate of 0.4% for Elunir, compared to 0.8% for Resolute (p=NS) with no events beyond 30 days for Elunir.

“The BIONICS data validated that the Elunir stent performed very well in a more broad, less selected ‘more comers’ population than has previously been studied for most other DES,” says David Kandzari, director of Interventional Cardiology at Piedmont Heart Institute, Atlanta, USA, and principal investigator for the BIONICS trial. “These results establish the excellent clinical performance of this stent, and we look forward to seeing the angiographic data over the next few months to further support its efficacy.”

In addition to the BIONICS study, new twelve month data from NIREUS, the European pivotal trial for Elunir, were presented at TCT. The NIREUS study, a prospective, multi-centre, randomised, non-inferiority pivotal study comparing Elunir to the Resolute Integrity Stent, met its non-inferiority primary end point of angiographic in-stent late loss at 6 months. These data were presented at EuroPCR in May 2016. The recent twelve month clinical data, presented TLF of 3.4% for EluNIR and 5.9% for Resolute (p=NS).These outcomes were consistent with the positive results of BIONICS.